Function Description:
The DIMTM system variable is used to control the minimum tolerance limit for dimension text when the DIMTOL or DIMLIM is on.
Type : Real
Saved in : Drawing
Initial value : 0.0000
The DIMTM system variable could recognize a value with symbols. If the DIMTOL is on and the settings of DIMTP and DIMTM are the same, it could create a tolerance value.
If the values of DIMTM and DIMTP are different, the upper tolerance is drawn above the lower, and a plus sign is added to the DIMTP value if it is positive.